Nitrogen machine first use need to check and pay attention to the problems

Catalogue:Industry NewsCTR:Time:2014-06-23 11:21:02

Article source:Responsible editor:

What do you need to pay attention to when the nitrogen machine is used for the first time?

制氮机首次使用需要检查和注意的问题

First, nitrogen machine start-up test

1.1 Check the device. The air is washed to 0.8MPa, the pipe joint is checked with soapy water without leakage, and the pressure balance is less than 0.03MPa after 2 hours (the effect of molecular sieve adsorption and temperature change should be excluded).

power

1.2, air compressor, cold and dry machine, nitrogen machine. Check the equipment's electrical system, instrumentation system, no loose connections, and head phenomena; Display instrumentation and electrical controls are reliable and have good safety, and the housing must be reliably grounded.

1.3. Check and open the intake valve of the air buffer tank and close the compressed air system of the bypass valve.

Second, the operation method of the nitrogen machine

2.1, Boot

2.1.1, turn on the power of the cold dryer and cool it for 3 to 5 minutes.

2.1.2, the air compressor is turned on, the compressed air enters the air storage tank of the cold dryer and filter processing, and the pressure gauge indicates a gradual rise.

2.1.3, until the pressure of the air buffer tank is 0.6MPa, open the control power switch cabinet, start the pressure swing adsorption nitrogen maker, you can enter the normal working state.

2.1.4, the nitrogen tank pressure is 0.6MPa, and then slowly open the exhaust valve, observe the flow meter float upward adjustment, for the user's requirements of nitrogen flow.

2.1.5, open the sampling valve, adjust the flow rate 400ml/min, find the nitrogen content index of the nitrogen analyzer, pay attention to the sampling flow rate should not be too large, as small as possible, 0.1-0.2 pressure, one hour later, generally half, into a stable state, adjust the nitrogen outlet flow control valve, to adjust the purity of nitrogen.

2.1.6, the operation of the system and whether the observed nitrogen system is switched on or off (can be determined according to the workflow's action gauge and the indication of changes).

2.2, Shutdown

Normal stop procedure

2.2.1, Device

A) Turn off the power switch.

B) Close the nitrogen supply valve and do not need to close other valves. If it is not for a long time, when the valve is closed.

C) Turn off the power switch of the cold and dry machine.

D) Turn off the power of the air compressor (such as the continuous supply of other equipment to the air compressor).

E) Close the compressed air valve and enter the nitrogen machine.

f) If the power supply is not cut off for a long time in each device

2.2.2, fault emergency shutdown procedures

A) Turn off the power switch.

B) Close the downstream flow of the valve.

C) Turn off the air compressor and the power switch of the cold and dry machine. Close the nitrogen supply valve. Close the compressed air valve and enter the nitrogen machine. Open air, nitrogen buffer tank drain valve and exhaust.

2.3, operation precautions:

2.3.1, according to the pressure of nitrogen production valve and adjust the flow front gas pressure regulating valve and gas flowmeter, do not increase the free flow to ensure the normal operation of equipment.

2.3.2, the intake valve opening valve should not be too large to ensure optimal purity.

2.3.3, the adjustment valve of the debugger will not rotate, so as not to affect the purity.

2.3.4, do not freely move the device in the electrical cabinet, do not freely pneumatic pipe valve.

2.3.5, the operator checks the pressure gauge on the machine and prepares a daily record of equipment failure analysis when the pressure changes.

2.3.6, regularly observe the outlet pressure, flow meter indication and nitrogen purity, control and page value performance, and solve problems in time.

2.3.7, complete daily operation records.

Description of the normal operating state of the equipment

3.1, the power indicator light, left suction, pressure, right suction light cycle shining indicates the nitrogen flow rate.

3.2, the left absorption, the pressure of the left adsorption column equilibrium pressure gradually rises to the highest, while the pressure of the right adsorption column gradually decreases to zero through the pressure equilibrium pressure.

3.3, pressure indicator light, left and right adsorption tower pressure will rise, fall, and gradually reach balance.

4, general repair and maintenance

In order to ensure long-term stable and reliable operation of the equipment system, users must do some maintenance work. The system's equipment random specifications are discussed in detail, please follow the maintenance instructions. It mainly includes:

(1) The solenoid valve works normally;

(2) Equipment, pipes, pipes or damage, water leakage and other phenomena;

(3) Whether the electrical control wiring of the equipment is firm and whether the electrical components are normal;

(4) Cleaning work.

            【Large Normal Small
Leave a comment Please consciously abide by the policies and regulations related to the Internet, and it is strictly forbidden to publish pornographic, violent and reactionary remarks.
Evaluate: Good Good Neutrality Neutrality Bad Bad
Emote:
Code: Refresh verification code  
Latest comments
Shenzhen Troy New energy Co., LTD©copyright2014    
Hot search: Nitrogen machine use PSA nitrogen machine principle PSA nitrogen machine instruction manual Nitrogen machine principle Nitrogen machine operation Nitrogen machine Nitrogen purification equipment Nitrogen machine maintenance Ammonia decomposition maintenance nitrogen machine pressure swing adsorption nitrogen production device

粤公网安备 44030902001891号

目前共有人访问过本网站
Scan code to get the latest product offers
Scan code to get the latest product offers