Nitrogen generator fault analysis and maintenance are as follows:
Fault phenomenon
Cause analysis
Elimination method
1. The indicator is off
electroless
The switch is not closed
Blown fuse
Power transmission
Close the switch
Check the circuit, change the fuse
2, the pneumatic valve does not operate
Air pressure < 0.4Mpa
The solenoid pilot valve does not operate
Debris in valve
Check the air pressure. Increase the pressure
Check PLC circuit
Cable falls off, reconnect
Pilot valve broken, replace
Open pneumatic valve and clear
3. The analyzer is inaccurate
The digital indicator blinks
The data display is unstable
Clear drop in indication
Electromagnetic interference, change the circuit
Purity beyond the range
Analyzer calibration
Oxygen electrode replacement
4, the system pressure difference is large
The air handling system has high resistance
Check the air lines, replace the parts
When the nitrogen machine equipment is faulty, it is forbidden to turn on the machine to reduce the damage again, communicate with the manufacturer to eliminate the fault in time, find out the cause of the fault for elimination, maintenance, replacement, start-up, and ensure the normal operation of the nitrogen machine equipment.
Before the maintenance and repair work of the nitrogen machine equipment, the power supply should be cut off, the doors and Windows should be opened to ensure that the indoor oxygen content is greater than or equal to 21%, and the ventilation monitoring work should be done to avoid causing the maintenance personnel to inhale too much nitrogen and suffocation, and the system devices and pipes are in a state of pressure. During the maintenance of the equipment, remove the air pressure of the AB tower of the nitrogen machine equipment, and be sure to reduce the pressure of each pipeline to zero in order to disassemble the pipeline and system components, otherwise the pressurized gas will immediately expand and spray out, which will directly or indirectly cause personal injury. Storage tanks, adsorption towers, and buffer tanks are all Class I pressure vessels, which should be slowly increased and reduced when opening and stopping.
Fault phenomenon
Cause analysis
Elimination method
1. The indicator is off
electroless
The switch is not closed
Blown fuse
Power transmission
Close the switch
Check the circuit, change the fuse
2, the pneumatic valve does not operate
Air pressure < 0.4Mpa
The solenoid pilot valve does not operate
Debris in valve
Check the air pressure. Increase the pressure
Check PLC circuit
Cable falls off, reconnect
Pilot valve broken, replace
Open pneumatic valve and clear
3. The analyzer is inaccurate
The digital indicator blinks
The data display is unstable
Clear drop in indication
Electromagnetic interference, change the circuit
Purity beyond the range
Analyzer calibration
Oxygen electrode replacement
4, the system pressure difference is large
The air handling system has high resistance
Check the air lines, replace the parts
When the nitrogen machine equipment is faulty, it is forbidden to turn on the machine to reduce the damage again, communicate with the manufacturer to eliminate the fault in time, find out the cause of the fault for elimination, maintenance, replacement, start-up, and ensure the normal operation of the nitrogen machine equipment.
Before the maintenance and repair work of the nitrogen machine equipment, the power supply should be cut off, the doors and Windows should be opened to ensure that the indoor oxygen content is greater than or equal to 21%, and the ventilation monitoring work should be done to avoid causing the maintenance personnel to inhale too much nitrogen and suffocation, and the system devices and pipes are in a state of pressure. During the maintenance of the equipment, remove the air pressure of the AB tower of the nitrogen machine equipment, and be sure to reduce the pressure of each pipeline to zero in order to disassemble the pipeline and system components, otherwise the pressurized gas will immediately expand and spray out, which will directly or indirectly cause personal injury. Storage tanks, adsorption towers, and buffer tanks are all Class I pressure vessels, which should be slowly increased and reduced when opening and stopping.
prev:Precautions for nitrogen making machine system equipment operation
next:What are the process processes of psa nitrogen making machine system?
Related information
- Application of nitrogen making machine in wire....
- Application of nitrogen-filled fresh-keeping t....
- Application of nitrogen machine in lithium bat....
- Nitrogen machine, nitrogen machine, nitrogen e....
- Application of nitrogen making machine in refl....
- Application of nitrogen making machine in high....
- Application of nitrogen making machine in plas....
- Application of nitrogen making machine in elec....
- Small food packaging nitrogen machine selection
- How to choose nitrogen machine equipment correctly
Leave a comment
Please consciously abide by the policies and regulations related to the Internet, and it is strictly forbidden to publish pornographic, violent and reactionary remarks.
Evaluate: | Good Neutrality Bad | ||||||||||||
Emote: |
|
Code:
Latest comments
Hot article:Nitrogen machine Pressure swing adsorption nitrogen production device | Nitrogen machine maintenance and ammonia decomposition maintenance | Nitrogen machine nitrogen purification equipment | Nitrogen machine operation and maintenance | What are the maintenance precautions of nitrogen machine| PSA nitrogen machine working principle | Working principle of nitrogen machine
Shenzhen Troy New energy Co., LTD©copyright2014
Hot search: Nitrogen machine use PSA nitrogen machine principle PSA nitrogen machine instruction manual Nitrogen machine principle Nitrogen machine operation Nitrogen machine Nitrogen purification equipment Nitrogen machine maintenance Ammonia decomposition maintenance nitrogen machine pressure swing adsorption nitrogen production device
目前共有人访问过本网站
Scan code to get the latest product offers |