How to deal with low outlet pressure of nitrogen machine

Catalogue:QuestionsCTR:Time:2017-06-12 11:52:32

Article source:Responsible editor:

The nitrogen outlet pressure of the nitrogen machine is low for the following reasons
1. The flow and pressure of the air compressor are not up to standard, and the pressure is less than 8 kg.
2. The air source pipeline is incorrectly connected, and the required compressed air cannot pass through.
3. The air source valve and the nitrogen regulator valve are not fully opened.
Solution: The flow and pressure of the configured air compressor meet the standards required by the nitrogen machine, and the air source pipeline is pressed
Install according to manufacturer's instructions and check that all valves are fully open.

            【Large Normal Small
Leave a comment Please consciously abide by the policies and regulations related to the Internet, and it is strictly forbidden to publish pornographic, violent and reactionary remarks.
Evaluate: Good Good Neutrality Neutrality Bad Bad
Emote:
Code: Refresh verification code  
Latest comments
Shenzhen Troy New energy Co., LTD©copyright2014    
Hot search: Nitrogen machine use PSA nitrogen machine principle PSA nitrogen machine instruction manual Nitrogen machine principle Nitrogen machine operation Nitrogen machine Nitrogen purification equipment Nitrogen machine maintenance Ammonia decomposition maintenance nitrogen machine pressure swing adsorption nitrogen production device

粤公网安备 44030902001891号

目前共有人访问过本网站
Scan code to get the latest product offers
Scan code to get the latest product offers